modbus: Fixed serial RX enablement for ASYNC and client mode
Modbus is failing to turn on RX when using serial ASYNC mode. This causes modbus to never receive inbound requests, leaving it inoperable. Additionally, modbus also enables RX when in client mode, leading to issues when running as a client. These have been fixed by enabling rx only when serial init is successful and modbus is in server mode during initialisation. Signed-off-by: Ryan Wiebe <ryan.wiebe@analog.com>
This commit is contained in:
committed by
Henrik Brix Andersen
parent
b76f37c5da
commit
8135c56cf6
@@ -693,10 +693,13 @@ int modbus_serial_init(struct modbus_context *ctx,
|
||||
if (!err) {
|
||||
k_timer_init(&cfg->rtu_timer, rtu_tmr_handler, NULL);
|
||||
k_timer_user_data_set(&cfg->rtu_timer, ctx);
|
||||
modbus_serial_rx_on(ctx);
|
||||
}
|
||||
}
|
||||
|
||||
if (!err && !ctx->client) {
|
||||
modbus_serial_rx_on(ctx);
|
||||
}
|
||||
|
||||
LOG_INF("RTU timeout %u us", cfg->rtu_timeout);
|
||||
|
||||
return err;
|
||||
|
||||
Reference in New Issue